View other products

TC65 MCB

TC65 2P

If you have any questions, please contact us!

C65 series Miniature Circuit Breaker is applied to protect the over-current of electrical apparatus
and circuit device of the construction and similar building in the circuit of AC 50Hz or 60Hz, max rated voltage230V, max rated current 63A. Under normal condition, it may be also applied as the unfrequent make-breaker operation.
This product conform to IEC60898, GB10963 standard.
1. Model: C65 1pole D curve
2. Name of article: Mini Circuit Breaker
3. Voltage: 230V/400V
4. Frequency: 50Hz/60Hz
5. Ampere(A): 1A,2A,3A,4A,6A,10A, 16A, 20A, 25A, 32A,40A,50A,63A
6. Rated current (A): 6KA
7. Carton size: 22.2×7.8×8.5
8 Qty of package: 12PCS/Lot
9. Tripping curve: D
10. Weight of MCB: 0.1KG/PCS
Characteristics
Protection against both overload and short circuit
High short-circuit capacity
Its frame and parts adopt plastics of high fire-resistant and shockproof
Small apperance.light weight
Comply with the standard IEC60898 and GB10963
General
1. Application: For protecting cables and equipments against overload and short circuit.
2. General rules for choosing MCB:
a. Technical data of the network at the point considered:
The earthing systems short-circuit current at the circuit breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage.
B.There are 3curve characteristics for magnetic operation:
B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuit; protection for resistive and inductive loads with low inrush current.
D curve (10-14 In) protection and control of the circuits against overloads and short-circuit; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
Specification


Standard

IEC/EN 60898-1

Electrical
 features

Rated Current In

A

1,2,3,4,6,10,16,20,25,32,40,50,63

Poles

P

1,2,3,4

Rated Voltage Ue

V

230/400

Insulation Voltage Ui

V

500

Rated Frequency

Hz

50/60

Rated Breaking Capacity

A

3000,4500

Rated Impulse withstand Voltage(1.2/50)Uimp

V

4000

Dielectric Test Voltage at ind.Freq.for
1min

Kv

2

Pollution Degree

 

2

Thermo-magnetic Release Characteristic

 

B,C,D

Mechanical
 features

Electrical Life

t

4000

Mechanical Life

t

10000

Protection Degree

 

IP20

Reference Temperature for Setting of
Thermal Element

°C

30

Ambient Temperature (with daily average
≤35°C)

°C

-5~+40(Special application please refer to temperature
compensation correction)

Storage Temperature

°C

-25~+70

Installation

Terminal Connection Type

 

Cable/Pin-type busbar

Terminal Size Top/Bottom for Cable

mm2

25

AWG

18-3

Terminal Size Top/Bottom for Busbar

mm2

25

AWG

18-3

Tightening Torque

N*m

2

In-lbs

18

Mounting

 

On DIN rail EN60715(35mm)by means of fast clip device

Connection

 

From top and bottom

Temperature Derating
Please refer to table below for temperature compensation correction


Rated Current In(A)

Temperature compensation coefficient under various operational temperature

-10°C

0°C

10°C

20°C

30°C

40°C

50°C

55°C

60°C

1-6

1.20

1.14

1.09

1.05

1.00

0.96

0.80

0.75

0.70

10-32

1.18

1.12

1.08

1.04

1.00

0.96

0.92

0.88

0.84

40-60

1.16

1.12

1.07

1.03

1.00

0.97

0.87

0.83

0.80

 

 

Email

accontactor@163.com
Email

Skype

snowyandsky
Skype

Skype

lily.hong9
Skype

Phone

0086-577-62125022
Phone